CHG1-325-110-35S/A
Hydrogen Cylinder - CHG1-325-110-35S/A
Where there is a risk of hydrogen embrittlement(see ISO11114-1), the Max. Rma shall be 880MPa, or, where Rea/Rma<0.9. be 950MPa. Compatibility statement: Cylinder according to classification QTS according ISO 11114-1 which can be used for gases indicated "A" in ISO11114-1;
Technical Requirements

     ▪  Application standard: EN ISO 9809-1:2019 and DIRECTIVE 97/23/EC

     ▪  Filling content: compressed gases or liquefied gases, except corrosive or embrittling gases (see ISO 11114-1)

     ▪  Maximum/minimum allowable temperature TS: -50°C to 65°C

     ▪  Material: 34CrMo4 (according to G8/T18248)

Chemical
Composition (%)
C Mn Si Cr Mo
0.30-0.37 0.60-0.90  0.15-0.35 0.90-1.20  0.15-0.30
S P S+P V+Nb+Ti+B+Zr
<0.010  <0.020 <0.025  <0.15

     ▪  Heat treatment: Quenched and Tempered

     ▪  Hydrostatic test pressure PT: 525bar

     ▪  Maximum allowable pressure PS: 350bar

     ▪  The permanent expansion shall not exceed 10% of the total volumetric expansion

     ▪  Spun-tube cylinder